Brief: Discover the IEC 60884-1:2022 VDE Type Switch Plug Socket Mechanical Endurance Tester, designed to test the durability of plugs, sockets, and linear switches. This advanced equipment features 3 synchronous workstations, PLC control, and a 7-inch touch-screen interface, ensuring compliance with international standards like IEC 60884-1:2022 and IEC60669-1.
Related Product Features:
3 synchronous workstations for testing plugs, sockets, or linear switches simultaneously.
Complies with IEC 60884-1:2022, IEC60669-1, and IEC60065:2014 standards.
Automatic stop and alarm for abnormal operation in any station.
Servo motor and ball screw drive for precise control.
7-inch color touch-screen display for easy parameter setting.
PLC control system for reliable and efficient operation.
Preset test times, speed, and stroke for customizable testing.
Aluminum alloy rack and stainless steel seal plate for durability.
FAQ's:
What standards does this tester comply with?
The tester complies with IEC 60884-1:2022 clause 20, 21, figure 16, IEC60669-1 clause 18 & 19, and IEC60065:2014 clause14.7 and clause 15.1.
How many workstations does the tester have?
The tester has 3 synchronous workstations, allowing simultaneous testing of 3 linear switches, plugs, or sockets.
What is the purpose of the endurance test?
The endurance test checks if switches, plugs, or sockets can withstand mechanical damage or electrical fatigue during normal operation, ensuring no contact adhesion or failure in on/off positions.